4. Place the four rubber spacers inside the SilenX new fan :


 

5. Before placing the new fan inside the Sony plastic housing, place the fan's wires like this:


 

6. Place the new SilenX fan with its four rubber spacers inside the Sony plastic housing :


 

Take care to keep the fan's connector on the right side of the plastic housing!

7. At this stage, update the SilenX white connector housing wiring to fit Sony wiring by swapping the +12V and SENSE wires :


 

8. Place the three pin header inside the SilenX connector housing:

 