Barco 120x/Cine9
Layout and Setup Tips
|
(Page 5)
|
Page:
1 2
3 4 5 6 |
Yoke board
Here is the yoke board with the H and V scan reversal switches on it. This
board is located on the inside of the CRT flip up metal shield. Three switches
reverse the H scan, one per tube, and one switch controls all three tubes for
the vertical switching of the scan. DO NOT touch these switches when the
set is on. Pressing one of them will instantly burn a line into one or
more of the tubes, and I get about 3 emails a year of people doing this…
This board fails rarely, although some of the vertical power resistors can
snap off on one side if they are bumped while working on the set.
|