CurtPalme.com Home Theater sales, calibration, service, and discussion forum. Hundreds of free manuals & setup tips.
   


 
Sign up and receive the latest newsletters by email!     Join the Forum discussions!    
    Site Map  
Home Products
For Sale
Referral
List
Photo
Gallery
Links Contact
Us
CRT Primer
Troubleshooting Tips
Mounting Methods
Definitive CRT
Projector Setup Guide
Tube/Raster Setup
Tube Condition (Wear)
Projector
Specifications
Projector Rankings
Video Processors
Ampro 1500/2000
Ampro 2300/2600
Ampro 3600/4600
Barco (Older Analog)
Barco 70x/Cine7  
Barco 500/800/801
Barco 808/Cine8
Barco 120x/Cine9
Dwin 500/700
Electrohome ECP 
Electrohome Marquee 
Mitsubishi
NEC PG
NEC XG
Panasonic 108x
Runco
Seleco
Sony 10xx
Sony 125x/127x
Sony 1292
Sony D50
Sony G70
Sony G90
Zenith 841/851
Zenith 895/900
Zenith 1200

Sony G70 (LC) Tube Swap

 (Page 6)

Back to Advanced Procedures Index

Page:
1 2 3 4 5 6 7 8 9 10
 

 



15. Place the new bare tube on the bench face down and prepare the cleaned HV cup this way (reversed vs wire output) using strong adhesive tape. This can ease the next operation:



16. Place HV silicon (Dow corning 3145RTV or equivalent) all around the tube’s HV hole. Do NOT put silicon WITHIN the hole:



17. Place the HV cup in the hole such that the metal anchor fits WITHIN the hole and press down on the cup in a circular motion such that the excess of silicon squeezes out around  the cup. Clean excess silicon off the tube:


LET THE TUBE SILICON COMPLETELY DRY BY LEAVING IT FOR 7 DAYS AT 20°C AMBIENT TEMPERATURE.